Checks to follow
Check that the machine is connected to the power outlet.
Check the good condition of the plug, cable, socket and fuses.
Check the correct operation of the front switch. In this case you can check the support video. In this case you can check the support video.
Check the input fuses. In this case you can check the support video.
Checks to follow
Check the Vacuum program configuration and set it.
Check the oil level and condition.
Check the oil outlet filter that is not saturated (replace it).
Check / replace the silicon lid gasket (ref. ZT0320226).
Verify the correct operation of the control board sensor (ref. ZT0232005).
Comprobar que no existan fugas de vacío (ref. ZT0280038).
Checks to follow
Check the setting of the sealing program and adjust it.
Verify the condition of the sealing wires (ref. ZT030S000) and of the teflon tape (ref. V0367).
Verify the condition of the silicone of the upper sealing bar.
Verify a good contact between the sealing bar and the lifting pistons.
Carry out a component verification test.
Checks to follow
Verify the gas spring (replace it).
Verify the correct operation of the micro switch on the lid (adjust).
Verify the valves unit.
Checks to follow
Verify and adjust the micro switch on the lid.
Verify the correct vacuum pump operation.
Checks to follow
Check if the lid opens and restart the machine.
Inform about the cycle repetition.
Checks to follow
Verify that the lid opens at the cycle end.
Checks to follow
Check / change oil outlet exhaust filter.
Checks to follow
Steps to follow to repair the machine: